No.1 Special Taizhong Avenue, Gaoqiao Industrial Park, Wujiashan Economic Development Zone, Wuhan, Hubei, China
Home ProductsSupercapacitor Battery Pack

Blue color 10.8V a supercapacitor battery pack for Smart meters , 3ER34615 + UPC1550

Certification
Good quality Li-SOCl2 Battery for sales
HCB Battery is a good company focusing on the product quality and services.

—— Miguel A. Novas

I find the good batteries with same good services here from HCB Battery.

—— Kent Heames

En coopération avec la société de HCB est très heureux, cela est une entreprise très professionnelle.

—— Jean-Marc Dupont

I'm Online Chat Now

Blue color 10.8V a supercapacitor battery pack for Smart meters , 3ER34615 + UPC1550

China Blue color 10.8V a supercapacitor battery pack for Smart meters , 3ER34615 + UPC1550 supplier
Blue color 10.8V a supercapacitor battery pack for Smart meters , 3ER34615 + UPC1550 supplier Blue color 10.8V a supercapacitor battery pack for Smart meters , 3ER34615 + UPC1550 supplier

Large Image :  Blue color 10.8V a supercapacitor battery pack for Smart meters , 3ER34615 + UPC1550

Product Details:

Place of Origin: Hubei Wuhan
Brand Name: HCB
Certification: UN/CE/UL
Model Number: 3ER34615 + UPC1550

Payment & Shipping Terms:

Minimum Order Quantity: ten thousand unit
Price: negotiable
Packaging Details: Special design for Air/Sea/Courier transportation
Delivery Time: 35 work days
Payment Terms: T/T, L/C
Supply Ability: two million unit per month
Contact Now
Detailed Product Description
Max Pulse Discharge Current: 5.0A Maximum Continuous Current: 2.0A
Model: 3ER34615 + UPC1550 Weight: 379.5g
Nominal Voltage: 10.8V Rated Capacity: 18000mAh

3ER34615 + UPC1550 , a supercapacitor battery pack for Smart meters​

 

Nominal Capacity 18000mAh
Battery discharged at continuous current 6.5mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage 3.6V
Maximum Continuous Current 2.0A
Battery with minimum 50% rated capacity discharged atambient temperature 23±2℃
Maximum Pulse Discharge Current 5.0A
Battery with minimum 50% rated capacity discharged at maxpulse for 3 seconds after 27seconds break. Ambient temperature23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature -55℃ to +85℃
Battery Dimension See drawing on pag
Max Weight 105g
Self-discharge Rate 2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life 10 years
Ambient temperature 23±2℃
 

1. Battery Characteristic

 

  • UPC(Ultra Pulse Capacitor)

An auxiliary battery capacitor designed for large pulse current.

 

The combination of UPC and lithium SOCl2 bobbin battery is more safety, and the combination can provide large discharge current. It’s a good choice toreplace spiral battery.

  • High Voltage

Consisting of 3 ER34615 batteries, can provide10.8V voltage. Single cell rated voltage 3.6V, the operating voltage varies with the load, normally between 3.3V and 3.6V.

  • High Energy Density

We provide the specific energy density up to 264Wh/kg

  • Wide Operating Temperature Range

The battery can be in work between -55℃ ~ +85℃

  • Stable Operating Voltage

Stable operating voltage, more than 90% of the capacity could be output with a fixed voltage

  • Long Shelf Life

The battery self-discharge less than 2% per year at room temperature

 

Hermetic welding sealing to reduce the leakage for extending the shelf life to more than 10 years

 

2. The working principle of UPC

 

Lithium SOCl2bobbin battery and UPC in parallel, high load of pulse completed by the Ultra Pulse Capacitor, not affected by the passivation.High load pulse bycompleted UPC, ahead of the next pulse lithium battery recharge UPC, after a full charge the discharge capacity ofUPC is constant, so on, until the battery capacity is completely consumed. In this way, we can guarantee the battery packa long life under the high load capacity.

 

3. Product application areas

 

  • Smart meters (clock battery)
  • Water meter
  • Gas meter
  • Heat meter
  • The OBU unit in intelligent transportation ETC
  • High voltage fault indicator
  • Patrolling unit
  • TPMS automobile tire pressure monitoring

 

4. FAQS of General Safety Instructions

 

  • How about the storage environment of the battery?

 

In order to store the battery, the environment should be dry enough.

 

  • When the abnormal heat release or leakage occurs, what should we do?

 

The battery should be stopped to using when the abnormal heat release or leakage occurs.

 

  • What is the first step when you would like to use our battery?

 

You need to read our manual before you need the battery.

 

  • What are you careful with if there are children beside when you use the battery?

 

Keep battery out of the children. If swallowed, please contact a physician at once.

 

  • If the batteries are closed to the fire, what may happen?

 

The batteries may be incinerated or mutilated if they are closed to the fire and it leads a possible burst or they may release the toxic materials.

 

 