Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsLithium Manganese Dioxide Battery

Lithium Manganese Dioxide CR14250 Lithium Battery Multiple Safety Design

China HCB Battery Co., Ltd certification
China HCB Battery Co., Ltd certification
HCB Battery is a good company focusing on the product quality and services.

—— Miguel A. Novas

I find the good batteries with same good services here from HCB Battery.

—— Kent Heames

En coopération avec la société de HCB est très heureux, cela est une entreprise très professionnelle.

—— Jean-Marc Dupont

I'm Online Chat Now

Lithium Manganese Dioxide CR14250 Lithium Battery Multiple Safety Design

Lithium Manganese Dioxide CR14250 Lithium Battery Multiple Safety Design
Lithium Manganese Dioxide CR14250 Lithium Battery Multiple Safety Design Lithium Manganese Dioxide CR14250 Lithium Battery Multiple Safety Design

Large Image :  Lithium Manganese Dioxide CR14250 Lithium Battery Multiple Safety Design

Product Details:

Place of Origin: Hubei Wuhan
Brand Name: HCB
Certification: UN/CE/UL
Model Number: CR14250

Payment & Shipping Terms:

Minimum Order Quantity: 1K pcs
Price: negotiable
Packaging Details: Special design for Air/Sea/Courier transportation
Delivery Time: 35 work days
Payment Terms: T/T, L/C
Supply Ability: two million unit per month
Detailed Product Description
Type: Non-Rechargeable Cellpacking: 304 Stainless Steel
Storage Life: 10 Years At Room Temperature Operating Temperature: -40℃~ +85℃
Weight(g): 10 Specific Energy: 180Wh/Kg
High Light:

lithium cell battery

,

lithium manganese dioxide cell

Lithium Manganese Dioxide CR14250 Lithium Battery Multiple Safety Design

 

 

 
Nominal Capacity 600mAh
Battery discharged at continuous current 1mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage 3.0 V
Maximum Continuous Current 500mA
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃
Maximum Pulse Discharge Current 1000mA
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature -40℃ to +85℃
Battery Dimension See drawing on pag
Max Weight 10.0g
Self-discharge Rate 2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life 10 years
Ambient temperature 23±2℃
 

 

1. Battery Characteristic

 

  • High Voltage

Single battery nominal voltage up to 3.0V

  • High Energy Density

Specific energy density up to 180Wh/kg

  • Wide Operating Temperature Range

We provide a wide operating temperature range, from -40℃ to +85℃

  • Long Shelf Life

Under the condition of normal temperature, the battery self -discharge rate of no more than 2% per year

 

High capacity, stable performance, stable discharge voltage, and no voltage passivation after long time storage

 

Battery sealing using the fully sealed structure to reduce the leakage of the battery, make the battery can be stored at room temperature for more than 10 years

 

The battery safety performance is good, high reliability, and pollution-free, environmental friendly.

 

2. Main Applications

 

  • Electrical equipment

Wireless electric power tools, computer RAM & COMS, UPS, CNC machine tools, (TPMS), camera, video camera, timer, calculator, electric toys, lighting equipment, etc.

  • Infrastructures

Automatic meters (water meter, electric meter, gas meter), conventional meters, etc.

  • Oil & gas

Well pressure meters in high temperature, float meter, logging while drilling (LWD), measure while drilling (MWD), etc.

 

3. Manufacturing Advantages

 

  • There is advanced automatic technology in HCB;
  • Cathode is produced by the unique advanced manufacturing process;
  • High power, high capacity(hermetic & semi sealing) or low temperature batteries are produced in HCB;
  • It is workable for us to provide multiple cascade and parallel connecting ways and combining suggestions with HCB customers;
  • The storage date is over 10 years to prove the reliability of the products.

 

4. Company Advantages

 

  • Quality management system of HCB is conformity with GB/T19001-2008/ISO9001:2008 standard;
  • Environment Management System of HCB is conformity with GB/T24001-2004/ISO14001:2004;
  • We have much experience in drop test package;
  • The goods can be transported very safely because we can provide the report for the customers' reference;
  • CE test is available for HCB Battery;
  • Rosh Standard is workable for HCB Battery;
  • The UL certificate can be given to you if required;

 

5. FAQS of General Safety Instructions

 

  • In order to keep the battery safely, what should we do?

 

In order to store the battery, the environment should be dry enough.

 

  • Is it ok to continue to use the battery when the abnormal heat release or leakage occurs?

 

The battery should be stopped to using when the abnormal heat release or leakage occurs.

 

  • What is the first step when you would like to use our battery?

 

The manual should be read before the battery is used.

 

  • What should you pay attention for when battery is put into the devices?

 

Follow the signs + and - shown on the batteries and appliances. Do not reverse battery. If batteries are put in the wrong way they are bound to become hot very quickly. This can lead to gas or toxic material leakage and/or to a violent rupture.

 

  • What the danger is if the battery is closed to the fire?

 

The batteries may be incinerated or mutilated if they are closed to the fire and it leads a possible burst or they may release the toxic materials.

 

  • If the positive and negative polarity of a battery is directly connected, what will happen?

 

If + and - polarity of battery is connected directly, it causes a short circuit and this may lead toxic gas and materials leakage or a big rupture.

 

  • Can the batteries be mixed to use on different electrochemical system, grades or brands?

 

When changing batteries be aware that batteries of different electrochemical system, grades, or brands should be not mixed. If different batteries are used or in case of using old and new batteries together this can discharge batteries due to different voltage or capacity. This can cause toxic material or gas leakage and/or violent rupture.

 