Home ProductsLi-SOCl2 Battery

Li-SOCl2 Long Life Lithium Battery 3.6 V For Telecommunications / Infrastructures Non-rechargeable NB IOT LORA

China HCB Battery Co., Ltd certification
China HCB Battery Co., Ltd certification
HCB Battery is a good company focusing on the product quality and services.

—— Miguel A. Novas

I find the good batteries with same good services here from HCB Battery.

—— Kent Heames

En coopération avec la société de HCB est très heureux, cela est une entreprise très professionnelle.

—— Jean-Marc Dupont

I'm Online Chat Now

Li-SOCl2 Long Life Lithium Battery 3.6 V For Telecommunications / Infrastructures Non-rechargeable NB IOT LORA

Li-SOCl2 Long Life Lithium Battery 3.6 V For Telecommunications / Infrastructures Non-rechargeable NB IOT LORA
Li-SOCl2 Long Life Lithium Battery 3.6 V For Telecommunications / Infrastructures Non-rechargeable NB IOT LORA Li-SOCl2 Long Life Lithium Battery 3.6 V For Telecommunications / Infrastructures Non-rechargeable NB IOT LORA

Large Image :  Li-SOCl2 Long Life Lithium Battery 3.6 V For Telecommunications / Infrastructures Non-rechargeable NB IOT LORA

Product Details:

Place of Origin: China
Brand Name: HCB
Certification: UN/CE/UL
Model Number: ER17335M

Payment & Shipping Terms:

Minimum Order Quantity: 1K pcs
Price: negotiable
Packaging Details: Special design for Air/Sea/Courier transportation
Delivery Time: 5 working days
Payment Terms: T/T, L/C
Supply Ability: two million unit per month
Detailed Product Description
Model: ER17335M Max Size(mm): Φ17.0×33.5
Weight: 21g Nominal Voltage: 3.6V
Nominal Capacity: 1800mAh Maximum Continuous Current: 340mA
High Light:

high power lithium battery

,

high temperature lithium battery

ER17335M Li-SOCl2 Long Life Lithium Battery 3.6 V For Telecommunications / Infrastructures

 

 

 

 

Nominal Capacity 1800mAh
Battery discharged at continuous current 3.4mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage 3.6 V
Maximum Continuous Current 340mA
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃
Maximum Pulse Discharge Current 680mA
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature -55℃ to +85℃
Battery Dimension See drawing on pag
Max Weight 21.0g
Self-discharge Rate 2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life 10 years
Ambient temperature 23±2℃

 

 

1. Battery Characteristic

 

  • High Voltage

The nominal voltage of single cell up to 3.6V, the operating voltage varies with the load, normally between 3.3V and 3.6V

  • High Energy Density

We offer the specific energy density of 308Wh/kg

  • Wide Operating Temperature Range

The battery with a strong adaptability to temperature can be in work between -55℃ ~ +85℃

  • Stable Operating Voltage

Stable operating voltage, more than 90% of the capacity could be output with a fixed voltage

  • Long Shelf Life

The battery self-discharge less than 2% per year at room temperature

 

Battery sealing using the fully sealed structure to reduce the leakage of the battery, make the battery can be stored at room temperature for more than 10 years

 

2. Main Applications

 

  • Telecommunications

Wireless telecommunication devices

  • Infrastructures

Automatic meters (water meter, electric meter, gas meter), conventional meters, etc.

  • Tracking

RFID products, road toll transponder, IC cards, etc.

 

3. Manufacturing Advantages

 

  • It is ok to use advance automatic technology in HCB;
  • The passivation is well controlled during the production;
  • Varity of solutions including high power, high capacity (hermetic & semi sealing), low temperature etc;
  • It is workable for us to provide multiple cascade and parallel connecting ways and combining suggestions with HCB customers;
  • Multiple safety design.
  • We have more than 20 years experience in the industrial technology of Li-SOCl2 batteries

 

4. Company Advantages

 

  • Quality management system of HCB is conformity with GB/T19001-2008/ISO9001:2008 standard;
  • HCB Environment Management System meets the standard GB/T24001-2004/ISO14001:2004;
  • Drop test package can be provided to your ordered battery if you need;
  • The goods can be transported very safely because we can provide the report for the customers' reference;
  • The CE certificate can be given to you if required;
  • Rosh test is available for HCB Battery;
  • We can provide you with the UL certificate if you need;

 

5. FAQS of General Safety Instructions

 

  • In order to keep the battery safely, what should we do?

 

The Battery should be stored in dry environment.

 

  • What is the first step when you would like to use our battery?

 

The manual should be read before the battery is used.

 

  • What are you careful with if there are children beside when you use the battery?

 

The battery should be kept out of the children firstly. If swallowed by children, please contact a physician at once.

 

  • What should you pay attention for when battery is put into the devices?

 

Follow the signs + and - shown on the batteries and appliances. Do not reverse battery. If batteries are put in the wrong way they are bound to become hot very quickly. This can lead to gas or toxic material leakage and/or to a violent rupture.

 

  • What the danger is if the battery is closed to the fire?

 

They are going to be hot in very short time and it will lead the leakage of gas and toxic materials which may cause a big rupture.

 

  • When the batteries are changed, what should you pay attention to?

 

When changing batteries be aware that batteries of different electrochemical system, grades, or brands should be not mixed. If different batteries are used or in case of using old and new batteries together this can discharge batteries due to different voltage or capacity. This can cause toxic material or gas leakage and/or violent rupture.

 

  • Is it workable to charge the primary batteries?

 

If you charge the primary batteries, it can lead to toxic material or gas leakage and maybe cause big rupture or fire.

 

Li-SOCl2 Long Life Lithium Battery 3.6 V For Telecommunications / Infrastructures Non-rechargeable NB IOT LORA 0

Contact Details
HCB Battery Co., Ltd

Contact Person: Angela

Tel: +8618907111907

Send your inquiry directly to us (0 / 3000)