Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsLi-SOCl2 Battery

ER26500M Primary Li-SOCl2 Lithium Battery GSM GAS Meter

China HCB Battery Co., Ltd certification
China HCB Battery Co., Ltd certification
HCB Battery is a good company focusing on the product quality and services.

—— Miguel A. Novas

I find the good batteries with same good services here from HCB Battery.

—— Kent Heames

En coopération avec la société de HCB est très heureux, cela est une entreprise très professionnelle.

—— Jean-Marc Dupont

I'm Online Chat Now

ER26500M Primary Li-SOCl2 Lithium Battery GSM GAS Meter

ER26500M Primary Li-SOCl2 Lithium Battery GSM GAS Meter
ER26500M Primary Li-SOCl2 Lithium Battery GSM GAS Meter

Large Image :  ER26500M Primary Li-SOCl2 Lithium Battery GSM GAS Meter

Product Details:

Place of Origin: China
Brand Name: HCB
Certification: UN/CE/UL
Model Number: ER26500M

Payment & Shipping Terms:

Minimum Order Quantity: 1K pcs
Price: negotiable
Packaging Details: Special design for Air/Sea/Courier transportation
Delivery Time: 15 work days
Payment Terms: T/T, L/C, D/P, D/A, L/C, Western Union, MoneyGram
Supply Ability: two million unit per month
Detailed Product Description
Cellpacking: 304 Stainless Steel Type: Non-Rechargeable
Operating Temperature: -55℃ ~ +85℃ Storage Life: 10 Years At Room Temperature
Energy Density: 475Wh/Kg Weight(g): 53
High Light:

ER26500M

,

saft lithium thionyl chloride

ER26500M Primary Li-SOCl2 Battery Spiral Type Customized Non-rechargeable GSM GAS Meter

 

 
Nominal Capacity 7000mAh
Battery discharged at continuous current 10mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage 3.6 V
Maximum Continuous Current 1000mA
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃
Maximum Pulse Discharge Current 2000mA
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature -55℃ to +85℃
Battery Dimension See drawing on pag
Max Weight 53.0g
Self-discharge Rate 2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life 10 years
Ambient temperature 23±2℃

 

 

1. Battery Characteristic

 

  • High Voltage

The nominal voltage of single cell up to 3.6V, the operating voltage varies with the load, normally between 3.3V and 3.6V

  • High Energy Density

The specific energy density of each battery is 475Wh/kg

  • Wide Operating Temperature Range

The battery with a strong adaptability to temperature can be in work between -55℃ ~ +85℃

  • Stable Operating Voltage

Stable operating voltage, more than 90% of the capacity could be output with a fixed voltage

  • Long Shelf Life

Under the condition of normal temperature, the battery self -discharge rate of no more than 2% per year

 

Hermetic welding sealing to reduce the leakage for extending the shelf life to more than 10 years

 

2. Main Applications

 

  • Tracking

RFID products, road toll transponder, IC cards, etc.

  • Security & alarms

Smoke detectors, security alarms, seismometers, locking system, monitoring system, etc.

  • Telecommunications

Wireless telecommunication devices

 

3. Manufacturing Advantages

 

  • It is ok to use advance automatic technology in HCB;
  • We can control the passivation of the battery very well;
  • We can produce high power, high capacity or high temperature batteries and so on;
  • The multiple cascade and parallel connecting ways and combining suggestions can be provided with you;
  • We have designed multiple safety solutions for Li-SOCl2 Battery;
  • We have more than 20 years experience in the industrial technology of Li-SOCl2 batteries.

 

4. Company Advantages

 

  • GB/T19001-2008/ISO9001:2008 is HCB quality management system standard;
  • GB/T24001-2004/ISO14001:2004 is HCB Environment Management System standard;
  • We have much experience in drop test package;
  • The goods can be transported very safely because we can provide the report for the customers' reference;
  • The CE certificate can be given to you if required;
  • The Rosh certificate can be given to you if required;
  • The UL certificate can be given to you if required;

 

5. FAQS of General Safety Instructions

 

  • In order to keep the battery safely, what should we do?

 

The battery should be kept as dryly as possible when they are in storage.

 

  • Is it ok to continue to use the battery when the abnormal heat release or leakage occurs?

 

We need to stop using the battery when the abnormal heat release or leakage occurs.

 

  • When the abnormal heat release or leakage occurs, what should we do?

 

We need to stop using the battery when the abnormal heat release or leakage occurs.

 

  • What is the first step when you would like to use our battery?

 

The manual should be read before the battery is used.

 

  • If the positive and negative polarity of a battery is directly connected, what will happen?

 

If + and - polarity of battery is connected directly, it causes a short circuit and this may lead toxic gas and materials leakage or a big rupture.

 

  • If the batteries are closed to the fire, what may happen?

 

They are going to be hot in very short time and it will lead the leakage of gas and toxic materials which may cause a big rupture.

 

  • Can the batteries be mixed to use on different electrochemical system, grades or brands?

 

When changing batteries be aware that batteries of different electrochemical system, grades, or brands should be not mixed.

 